China Council for the Promotion of International Trade(CCPIT)
特点和优势和应用
FEATURES & BENEFITS:
> Dual seal system with PIB primary, polysulphide or silicone secondary seals;
> Substantially reduced perimeter condensation;
> Lower thermal conductivity than aluminium spacer units (typical U-Value improvement of 0.2 W/m2k);
> Excellent UV resistance;
> Spacer appearance is a smooth matte dark grey finish;
> Spacer range 9/12/16/18/20/22mm;
> Secondary seal default is Polysulphide. Specify Silicone seal if edges of IGU are exposed.
APPLICATIONS
ENERGY & CLIMATE
For improved energy efficiency with greater solar and thermal control, with High performance Low-E coating. Alternatively, laminated glass panels with solar control interlayers can also be incorporated into units. The unique properties of laminated glass also block out up to 99% of harmful UV light.
NOISE
Reducing noise is better achieved through Acoustic laminated glass panels when compared to ordinary single
glass.
SAFETY & SECURITY
IGU units can be made with either Toughened or Laminated safety glass. Two panels of glass also make it harder to breach the window or door opening compared to ordinary single glass, but for greater security,
build laminated panels with extra thick 1.52mm PVB or structural interlayers such as SentryGlas®Plus. All
IGU units are supplied as standard
STRUCTURAL & STRENGTH
The air space in IGU’s in conjunction with two panels of glass act as a ‘shock absorber’ or ‘spring’ allowing higher
wind loads to be applied compared to equivalent single glass thickness.
IGU DESIGN AND GLAZING NOTES
PRODUCT SPECIFICATIONS
Maximum Size 4500mm x 2400mm
Minimum Size 800mm x 300mm
Maximum thickness 15mm glass + Spacer width + 15mm glass
Minimum thickness 5mm + 9mm space + 5mm
Glass Types
All clear, tinted and low-E float annealed, tempered, laminated,
Dual Seal Primary and secondary sealed units
Primary PIB (Polyisobutyl)
Secondary
Default applied is Polysulphide;
Silicone applied for exposed edged glazing, min inset depth of 6mm.