Beijing Aeonmed Co., LTD. China
Other
send
question_answer
badge
Aeon8800A
Anesthesia Machine--8800A
The Aeon8800A Anesthesia Workstation is a high-level device from AEONMED, engineered based on clinical input and feedback. The workstation has a user-friendly design, incorporates innovative technology, and provides the clinician with safe and effective treatment options for patients. A. Modern Breathing Circuit 1)Safe, stable and efficient anesthesia management; 2)The characteristic breathing circuit is made of alloy, resistant to corrosion and can withstand repeated high temperature and high-pressure sterilization; 3)Adjustable angle, easy to install, many user-friendly designs make maintenance easier; 4)The integrated heating system with a better thermal conductivity of alloy help prevent condensation and make patients feel more comfortable; 5)APL with fast release pressure, the upper pressure limit is accurately adjustable, avoiding repeated operations and improving anesthesia efficiency; 6)The Breathing Circuit has CO2 bypass function. B. Lung-Protective Ventilation 1)Lung-protective ventilation is the current standard of care for mechanical ventilation. The risk of Postoperative Pulmonary Complications (PPCs) can be effectively reduced through Lung-protective ventilation strategy; 2)Minimized impact recruitment maneuver C. Low tidal volume The 8800A has a minimum tidal volume of 10ml in volume control mode, in addition to possessing the PCV-VG and BIVENT ventilation mode, helping to achieve the precise low tidal volume required during lung protective ventilation. D. Individualized PEEP titration tool Stress index (SI) monitoring helps with Individualized PEEP titration. Through the guidance of the Static PV loop tool, the appropriate setting of PEEP value and tidal volume are realized. E. Minimized impact recruitment maneuver Two types recruitment maneuvers: stepwise PEEP or sustained inflation. Automate repetitive tasks used during lung ventilation procedures. F. Enhanced monitoring and clinical tools 1)In addition to traditional monitoring parameters, special monitoring parameters, such as Driving Pressure (DP), are provided to guide clinicians in adjusting ventilation parameters. 2)Spirometry loops can be stored for future reference, allowing clinicians the ability to better understand changes in the patient* s response to therapy. 3)Provide multiple of cardiopulmonary bypass modes (CBP) to assist in the implementation of cardiopulmonary bypass surgery. 4)Continuous trend information together with time discrete events are stored and shown in the table or chart. 5)Provides medical gas consumption calculations: including O2, N2O and Agent. And provide calculations of CO2 production. 6)International standard data protocol support to connect to internet center of hospitals. G. Ventilator-level ventilation modes 1)Aeon8800A is always your professional guard for lives, offering comprehensive and accurate respiratory care for all the patient types from infant to adult, helping clinicians to have more solutions for different clinical situations; 2)Combines the advantages of VCV and PCV providing better oxygenation with lower peak inspiratory pressure; 3)Guarantees patients can breathe spontaneously between mandatory breaths with pressure support as a backup. It offers flexible respiratory solutions when anesthesia steps into different phases; 4)Pressure controlled breaths are provided by switching between a high and low airway pressure in an adjustable time sequence. Spontaneous breaths can be pressure supported at the high and low pressure levels. H. Intelligent operations bring cost-efficient management, Digital Flowmeter with ECO-Optimizer 1)Digital Flowmeter makes fresh gas flow setting easier and more precise. 2)The ECO-Optimizer indicates the recommended fresh gas flow setting according to the setting value and the minimum 6 needed of the patient. It enables a safe Low Flow, and reduces the waste of anesthetic agents and medical gases. 3)By first using compressed air as the drive gas, Driven Gas Auto-Switch to reduce oxygen consumption, also ensure the patient is ventilated uninterruptedly; 4) When the compressed air supply is disrupted, the Aeon8800Awill automatically switch to O2 driving gas.
Help Center

Legal Consulting

support_agent
Support

share
Social Share